Browse files

serial: max310x: set default value when reading clock ready bit

commit 04193733 upstream.

If regmap_read() returns a non-zero value, the 'val' variable can be left
uninitialized.

Clear it before calling regmap_read() to make sure we properly detect
the clock ready bit.

Fixes: 4cf9a888

 ("serial: max310x: Check the clock readiness")