Commit 68ff3812 authored by Jonathan Cameron's avatar Jonathan Cameron Committed by Greg Kroah-Hartman
Browse files

iio:health:afe4404 Fix timestamp alignment and prevent data leak.

[ Upstream commit f88eccca ]

One of a class of bugs pointed out by Lars in a recent review.
iio_push_to_buffers_with_timestamp assumes the buffer used is aligned
to the size of the timestamp (8 bytes).  This is not guaranteed in
this driver which uses a 40 byte array of smaller elements on the stack.
As Lars also noted this anti pattern can involve a leak of data to
userspace and that indeed can happen here.  We close both issues by
moving to a suitable structure in the iio_priv() data with alignment
explicitly requested.  This data is allocated with kzalloc so no
data can leak appart from previous readings.

Fixes: 87aec56e

 ("iio: health: Add driver for the TI AFE4404 heart monitor")
Reported-by: default avatarLars-Peter Clausen <lars@metafoo.de>
Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
Acked-by: default avatarAndrew F. Davis <afd@ti.com>
Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: default avatarSasha Levin <sashal@kernel.org>