Skip to content
Commit 39abe9d8 authored by Iker Perez del Palomar Sustatxa's avatar Iker Perez del Palomar Sustatxa Committed by Guenter Roeck
Browse files

hwmon: (lm75) Add support for TMP75B



The TMP75B has a different control register, supports 12-bit
resolution and the default conversion rate is 37 Hz.

Signed-off-by: default avatarIker Perez del Palomar Sustatxa <iker.perez@codethink.co.uk>
Signed-off-by: default avatarGuenter Roeck <linux@roeck-us.net>
parent be889be7