Skip to content
Commit 3618e591 authored by Heiner Kallweit's avatar Heiner Kallweit Committed by Greg Kroah-Hartman
Browse files

r8169: fix issue with confused RX unit after PHY power-down on RTL8411b

[ Upstream commit fe4e8db0 ]

On RTL8411b the RX unit gets confused if the PHY is powered-down.
This was reported in [0] and confirmed by Realtek. Realtek provided
a sequence to fix the RX unit after PHY wakeup.

The issue itself seems to have been there longer, the Fixes tag
refers to where the fix applies properly.

[0] https://bugzilla.redhat.com/show_bug.cgi?id=1692075

Fixes: a99790bf

 ("r8169: Reinstate ASPM Support")
Tested-by: default avatarIonut Radu <ionut.radu@gmail.com>
Signed-off-by: default avatarHeiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent e1f7bc51
0% or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment