serial: meson: fix meson_serial_pending() tx logic
According to the dm_serial_ops documentation, pending() should: > @return number of waiting characters, 0 for none, -ve on error And: > It is acceptable to return 1 if an indeterminant number > of characters is waiting. With the current implementation, we have: * FIFO is full -> pending() returns 0 * FIFO is partially used -> pending() returns 1 * FIFO is empty -> pending() returns 1 This is not the same as what the documentation requires. Moreover, since [1], arm reset now flushes all console devices (including serial) before the cpu gets reset. Because of the flawed logic: => reset # user calls reset flush() is called _serial_flush() is called ops->pending(dev, false) # never returns false # board hangs indefinitely without resetting. Fix it by using AML_UART_TX_EMPTY instead of AML_UART_TX_FULL. [1] commit c5f4cdb8 ("console: Use flush() before panic and reset"), Signed-off-by:Mattijs Korpershoek <mkorpershoek@baylibre.com> Acked-by:
Neil Armstrong <neil.armstrong@linaro.org> Link: https://lore.kernel.org/r/20230606-fix-meson-serial-pending-v1-1-6a54d4a01f76@baylibre.com Signed-off-by:
Neil Armstrong <neil.armstrong@linaro.org>