net: phy: marvell: fix detection of PHY on Topaz switches
stable inclusion from stable-5.10.32 commit 6ac98ee9cb7c62d2990e984b0df4d443a7769bc2 bugzilla: 51796 -------------------------------- commit 1fe976d3 upstream. Since commit fee2d546 ("net: phy: marvell: mv88e6390 temperature sensor reading"), Linux reports the temperature of Topaz hwmon as constant -75°C. This is because switches from the Topaz family (88E6141 / 88E6341) have the address of the temperature sensor register different from Peridot. This address is instead compatible with 88E1510 PHYs, as was used for Topaz before the above mentioned commit. Create a new mapping table between switch family and PHY ID for families which don't have a model number. And define PHY IDs for Topaz and Peridot families. Create a new PHY ID and a new PHY driver for Topaz's internal PHY. The only difference from Peridot's PHY driver is the HWMON probing method. Prior this change Topaz's internal PHY is detected by kernel as: PHY [...] driver [Marvell 88E6390] (irq=63) And afterwards as: PHY [...] driver [Marvell 88E6341 Family] (irq=63) Signed-off-by:Pali Rohár <pali@kernel.org> BugLink: https://github.com/globalscaletechnologies/linux/issues/1 Fixes: fee2d546 ("net: phy: marvell: mv88e6390 temperature sensor reading") Reviewed-by:
Marek Behún <kabel@kernel.org> Reviewed-by:
Andrew Lunn <andrew@lunn.ch> Signed-off-by:
David S. Miller <davem@davemloft.net> Signed-off-by:
Greg Kroah-Hartman <gregkh@linuxfoundation.org> Signed-off-by:
Chen Jun <chenjun102@huawei.com> Acked-by:
Weilong Chen <chenweilong@huawei.com> Signed-off-by:
Zheng Zengkai <zhengzengkai@huawei.com>