power: supply: bq24190: Call power_supply_changed() after updating input current
stable inclusion from stable-v5.10.182 commit b557220d31409eed7bcc5d7f70c3fa5fcd390435 category: bugfix bugzilla: https://gitee.com/openeuler/kernel/issues/I8GJZJ Reference: https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git/commit/?id=b557220d31409eed7bcc5d7f70c3fa5fcd390435 -------------------------------- [ Upstream commit 77c2a309 ] The bq24192 model relies on external charger-type detection and once that is done the bq24190_charger code will update the input current. In this case, when the initial power_supply_changed() call is made from the interrupt handler, the input settings are 5V/0.5A which on many devices is not enough power to charge (while the device is on). On many devices the fuel-gauge relies in its external_power_changed callback to timely signal userspace about charging <-> discharging status changes. Add a power_supply_changed() call after updating the input current. This allows the fuel-gauge driver to timely recheck if the battery is charging after the new input current has been applied and then it can immediately notify userspace about this. Fixes: 18f8e6f6 ("power: supply: bq24190_charger: Get input_current_limit from our supplier") Signed-off-by:Hans de Goede <hdegoede@redhat.com> Signed-off-by:
Sebastian Reichel <sebastian.reichel@collabora.com> Signed-off-by:
Sasha Levin <sashal@kernel.org> Signed-off-by:
sanglipeng <sanglipeng1@jd.com> (cherry picked from commit 2166a7fb)