staging: comedi: das6402: Fix endian problem for AI command data
stable inclusion from stable-5.10.24 commit d8f26a4122dbb9202edafa73a9e3288485c3f7e5 bugzilla: 51348 -------------------------------- commit 1c0f20b7 upstream. The analog input subdevice supports Comedi asynchronous commands that use Comedi's 16-bit sample format. However, the call to `comedi_buf_write_samples()` is passing the address of a 32-bit integer variable. On bigendian machines, this will copy 2 bytes from the wrong end of the 32-bit value. Fix it by changing the type of the variable holding the sample value to `unsigned short`. Fixes: d1d24cb6 ("staging: comedi: das6402: read analog input samples in interrupt handler") Cc: <stable@vger.kernel.org> # 3.19+ Signed-off-by:Ian Abbott <abbotti@mev.co.uk> Link: https://lore.kernel.org/r/20210223143055.257402-5-abbotti@mev.co.uk Signed-off-by:
Greg Kroah-Hartman <gregkh@linuxfoundation.org> Signed-off-by:
Chen Jun <chenjun102@huawei.com> Acked-by:
Weilong Chen <chenweilong@huawei.com> Signed-off-by:
Zheng Zengkai <zhengzengkai@huawei.com>