hwmon: (pmbus/bpa-rs600) Handle Vin readings >= 256V



The BPA-RS600 doesn't follow the PMBus spec for linear data.
Specifically it treats the mantissa as an unsigned 11-bit value instead
of a two's complement 11-bit value. At this point it's unclear whether
this only affects Vin or if Pin/Pout1 are affected as well. Erring on
the side of caution only Vin is dealt with here.

Fixes: 15b2703e ("hwmon: (pmbus) Add driver for BluTek BPA-RS600")
Signed-off-by: default avatarChris Packham <chris.packham@alliedtelesis.co.nz>
Link: https://lore.kernel.org/r/20210616034218.25821-1-chris.packham@alliedtelesis.co.nz


Signed-off-by: default avatarGuenter Roeck <linux@roeck-us.net>