While normal Dual and Quad SPI Transfers are unidirectional, we must do a bidirectional transfer if loopback mode is enabled, else rx_buf is not filled. With spidev it seemed to work, as spidev uses the same buffer for tranmission and reception. Signed-off-by:Geert Uytterhoeven <geert+renesas@linux-m68k.org> Signed-off-by:
Mark Brown <broonie@linaro.org>