Commit 64604957 authored by James Wang's avatar James Wang Committed by Jens Axboe
Browse files

Fix loop device flush before configure v3



While installing SLES-12 (based on v4.4), I found that the installer
will stall for 60+ seconds during LVM disk scan.  The root cause was
determined to be the removal of a bound device check in loop_flush()
by commit b5dd2f60 ("block: loop: improve performance via blk-mq").

Restoring this check, examining ->lo_state as set by loop_set_fd()
eliminates the bad behavior.

Test method:
modprobe loop max_loop=64
dd if=/dev/zero of=disk bs=512 count=200K
for((i=0;i<4;i++))do losetup -f disk; done
mkfs.ext4 -F /dev/loop0
for((i=0;i<4;i++))do mkdir t$i; mount /dev/loop$i t$i;done
for f in `ls /dev/loop[0-9]*|sort`; do \
	echo $f; dd if=$f of=/dev/null  bs=512 count=1; \
	done

Test output:  stock          patched
/dev/loop0    18.1217e-05    8.3842e-05
/dev/loop1     6.1114e-05    0.000147979
/dev/loop10    0.414701      0.000116564
/dev/loop11    0.7474        6.7942e-05
/dev/loop12    0.747986      8.9082e-05
/dev/loop13    0.746532      7.4799e-05
/dev/loop14    0.480041      9.3926e-05
/dev/loop15    1.26453       7.2522e-05

Note that from loop10 onward, the device is not mounted, yet the
stock kernel consumes several orders of magnitude more wall time
than it does for a mounted device.
(Thanks for Mike Galbraith <efault@gmx.de>, give a changelog review.)

Reviewed-by: default avatarHannes Reinecke <hare@suse.com>
Reviewed-by: default avatarMing Lei <ming.lei@redhat.com>
Signed-off-by: default avatarJames Wang <jnwang@suse.com>
Fixes: b5dd2f60 ("block: loop: improve performance via blk-mq")
Signed-off-by: default avatarJens Axboe <axboe@fb.com>
parent 6679a90c
0% or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!