thermal: devfreq_cooling: use local ops instead of global ops
Fix access illegal address problem in following condition: There are multiple devfreq cooling devices in system, some of them has EM model but others do not. Energy model ops such as state2power will append to global devfreq_cooling_ops when the cooling device with EM model is registered. It makes the cooling device without EM model also use devfreq_cooling_ops after appending when registered later by of_devfreq_cooling_register_power() or of_devfreq_cooling_register(). The IPA governor regards the cooling devices without EM model as a power actor, because they also have energy model ops, and will access illegal address at dfc->em_pd when execute cdev->ops->get_requested_power, cdev->ops->state2power or cdev->ops->power2state. Fixes: 615510fe ("thermal: devfreq_cooling: remove old power model and use EM") Cc: 5.13+ <stable@vger.kernel.org> # 5.13+ Signed-off-by: Kant Fan <kant@allwinnertech.com> Reviewed-by: Lukasz Luba <lukasz.luba@arm.com> Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>