Skip to content
Commit 7b4ab4ab authored by Eddie James's avatar Eddie James Committed by Jonathan Cameron
Browse files

iio: pressure: dps310: Reset chip after timeout



The DPS310 chip has been observed to get "stuck" such that pressure
and temperature measurements are never indicated as "ready" in the
MEAS_CFG register. The only solution is to reset the device and try
again. In order to avoid continual failures, use a boolean flag to
only try the reset after timeout once if errors persist.

Fixes: ba6ec48e ("iio: Add driver for Infineon DPS310")
Cc: <stable@vger.kernel.org>
Signed-off-by: default avatarEddie James <eajames@linux.ibm.com>
Reviewed-by: default avatarAndy Shevchenko <andy.shevchenko@gmail.com>
Link: https://lore.kernel.org/r/20220915195719.136812-3-eajames@linux.ibm.com


Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
parent c2329717