iio:chemical:pms7003: Fix timestamp alignment and prevent data leak.
commit 13e94563 upstream. One of a class of bugs pointed out by Lars in a recent review. iio_push_to_buffers_with_timestamp assumes the buffer used is aligned to the size of the timestamp (8 bytes). This is not guaranteed in this driver which uses an array of smaller elements on the stack. As Lars also noted this anti pattern can involve a leak of data to userspace and that indeed can happen here. We close both issues by moving to a suitable structure in the iio_priv() data with alignment explicitly requested. This data is allocated with kzalloc so no data can leak appart from previous readings. Fixes: a1d64226 ("iio: chemical: add support for Plantower PMS7003 sensor") Reported-by: Lars-Peter Clausen <lars@metafoo.de> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Cc: <Stable@vger.kernel.org> Acked-by: Tomasz Duszynski <tomasz.duszynski@octakon.com> Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com>