thermal/drivers/mediatek/lvts_thermal: Don't leave threshold zeroed



The thermal framework might leave the low threshold unset if there
aren't any lower trip points. This leaves the register zeroed, which
translates to a very high temperature for the low threshold. The
interrupt for this threshold is then immediately triggered, and the
state machine gets stuck, preventing any other temperature monitoring
interrupts to ever trigger.

(The same happens by not setting the Cold or Hot to Normal thresholds
when using those)

Set the unused threshold to a valid low value. This value was chosen so
that for any valid golden temperature read from the efuse, when the
value is converted to raw and back again to milliCelsius, the result
doesn't underflow.

Fixes: f5f633b1 ("thermal/drivers/mediatek: Add the Low Voltage Thermal Sensor driver")
Signed-off-by: default avatarNícolas F. R. A. Prado <nfraprado@collabora.com>
Reviewed-by: default avatarAlexandre Mergnat <amergnat@baylibre.com>
Reviewed-by: default avatarAngeloGioacchino Del Regno <angelogioacchino.delregno@collabora.com>
Signed-off-by: default avatarDaniel Lezcano <daniel.lezcano@linaro.org>