Skip to content
Commit 2edd0078 authored by Vasileios Amoiridis's avatar Vasileios Amoiridis Committed by Greg Kroah-Hartman
Browse files

iio: chemical: bme680: Fix calibration data variable

commit b47c0fee upstream.

According to the BME68x Sensor API [1], the h6 calibration
data variable should be an unsigned integer of size 8.

[1]: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x_defs.h#L789

Fixes: 1b3bd859

 ("iio: chemical: Add support for Bosch BME680 sensor")
Signed-off-by: default avatarVasileios Amoiridis <vassilisamir@gmail.com>
Link: https://lore.kernel.org/r/20240606212313.207550-3-vassilisamir@gmail.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent 093d5725
0% or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment