Skip to content
Commit 19722ecb authored by Russell King's avatar Russell King Committed by Paul Gortmaker
Browse files

net: marvell: mvpp2: phylink requires the link interrupt



commit f3f2364e upstream.

phylink requires the MAC to report when its link status changes when
operating in inband modes.  Failure to report link status changes
means that phylink has no idea when the link events happen, which
results in either the network interface's carrier remaining up or
remaining permanently down.

For example, with a fiber module, if the interface is brought up and
link is initially established, taking the link down at the far end
will cut the optical power.  The SFP module's LOS asserts, we
deactivate the link, and the network interface reports no carrier.

When the far end is brought back up, the SFP module's LOS deasserts,
but the MAC may be slower to establish link.  If this happens (which
in my tests is a certainty) then phylink never hears that the MAC
has established link with the far end, and the network interface is
stuck reporting no carrier.  This means the interface is
non-functional.

Avoiding the link interrupt when we have phylink is basically not
an option, so remove the !port->phylink from the test.

Fixes: 4bb04326 ("net: mvpp2: phylink support")
Tested-by: default avatarSven Auhagen <sven.auhagen@voleatech.de>
Tested-by: default avatarAntoine Tenart <antoine.tenart@bootlin.com>
Signed-off-by: default avatarRussell King <rmk+kernel@armlinux.org.uk>
Signed-off-by: default avatarJakub Kicinski <jakub.kicinski@netronome.com>
Signed-off-by: default avatarPaul Gortmaker <paul.gortmaker@windriver.com>
parent 494719dd