Commit ef63461c authored by Russell King (Oracle)'s avatar Russell King (Oracle) Committed by David S. Miller
Browse files

net: pcs: xpcs: remove double-read of link state when using AN



Phylink does not want the current state of the link when reading the
PCS link state - it wants the latched state. Don't double-read the
MII status register. Phylink will re-read as necessary to capture
transient link-down events as of dbae3388 ("net: phylink: Force
retrigger in case of latched link-fail indicator").

The above referenced commit is a dependency for this change, and thus
this change should not be backported to any kernel that does not
contain the above referenced commit.

Fixes: fcb26bd2 ("net: phy: Add Synopsys DesignWare XPCS MDIO module")
Signed-off-by: default avatarRussell King (Oracle) <rmk+kernel@armlinux.org.uk>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent abf36703
Loading
Loading
Loading
Loading
+2 −11
Original line number Diff line number Diff line
@@ -321,7 +321,7 @@ static int xpcs_read_fault_c73(struct dw_xpcs *xpcs,
	return 0;
}

static int xpcs_read_link_c73(struct dw_xpcs *xpcs, bool an)
static int xpcs_read_link_c73(struct dw_xpcs *xpcs)
{
	bool link = true;
	int ret;
@@ -333,15 +333,6 @@ static int xpcs_read_link_c73(struct dw_xpcs *xpcs, bool an)
	if (!(ret & MDIO_STAT1_LSTATUS))
		link = false;

	if (an) {
		ret = xpcs_read(xpcs, MDIO_MMD_AN, MDIO_STAT1);
		if (ret < 0)
			return ret;

		if (!(ret & MDIO_STAT1_LSTATUS))
			link = false;
	}

	return link;
}

@@ -935,7 +926,7 @@ static int xpcs_get_state_c73(struct dw_xpcs *xpcs,
	int ret;

	/* Link needs to be read first ... */
	state->link = xpcs_read_link_c73(xpcs, state->an_enabled) > 0 ? 1 : 0;
	state->link = xpcs_read_link_c73(xpcs) > 0 ? 1 : 0;

	/* ... and then we check the faults. */
	ret = xpcs_read_fault_c73(xpcs, state);