Loading Documentation/power/regulator/consumer.txt +1 −1 Original line number Diff line number Diff line Loading @@ -137,7 +137,7 @@ Indirect operating mode control. Consumer drivers can request a change in their supply regulator operating mode by calling :- int regulator_set_optimum_mode(struct regulator *regulator, int load_uA); int regulator_set_load(struct regulator *regulator, int load_uA); This will cause the core to recalculate the total load on the regulator (based on all its consumers) and change operating mode (if necessary and permitted) Loading drivers/regulator/core.c +4 −4 Original line number Diff line number Diff line Loading @@ -2994,7 +2994,7 @@ unsigned int regulator_get_mode(struct regulator *regulator) EXPORT_SYMBOL_GPL(regulator_get_mode); /** * regulator_set_optimum_mode - set regulator optimum operating mode * regulator_set_load - set regulator load * @regulator: regulator source * @uA_load: load current * Loading @@ -3017,9 +3017,9 @@ EXPORT_SYMBOL_GPL(regulator_get_mode); * DRMS will sum the total requested load on the regulator and change * to the most efficient operating mode if platform constraints allow. * * Returns the new regulator mode or error. * On error a negative errno is returned. */ int regulator_set_optimum_mode(struct regulator *regulator, int uA_load) int regulator_set_load(struct regulator *regulator, int uA_load) { struct regulator_dev *rdev = regulator->rdev; int ret; Loading @@ -3031,7 +3031,7 @@ int regulator_set_optimum_mode(struct regulator *regulator, int uA_load) return ret; } EXPORT_SYMBOL_GPL(regulator_set_optimum_mode); EXPORT_SYMBOL_GPL(regulator_set_load); /** * regulator_allow_bypass - allow the regulator to go into bypass mode Loading include/linux/regulator/consumer.h +9 −3 Original line number Diff line number Diff line Loading @@ -238,7 +238,7 @@ int regulator_get_current_limit(struct regulator *regulator); int regulator_set_mode(struct regulator *regulator, unsigned int mode); unsigned int regulator_get_mode(struct regulator *regulator); int regulator_set_optimum_mode(struct regulator *regulator, int load_uA); int regulator_set_load(struct regulator *regulator, int load_uA); int regulator_allow_bypass(struct regulator *regulator, bool allow); Loading Loading @@ -479,8 +479,7 @@ static inline unsigned int regulator_get_mode(struct regulator *regulator) return REGULATOR_MODE_NORMAL; } static inline int regulator_set_optimum_mode(struct regulator *regulator, int load_uA) static inline int regulator_set_load(struct regulator *regulator, int load_uA) { return REGULATOR_MODE_NORMAL; } Loading Loading @@ -555,4 +554,11 @@ static inline int regulator_is_supported_voltage_tol(struct regulator *regulator target_uV + tol_uV); } /* TEMP: Wrapper to keep bisectability */ static inline int regulator_set_optimum_mode(struct regulator *regulator, int load_uA) { return regulator_set_load(regulator, load_uA); } #endif Loading
Documentation/power/regulator/consumer.txt +1 −1 Original line number Diff line number Diff line Loading @@ -137,7 +137,7 @@ Indirect operating mode control. Consumer drivers can request a change in their supply regulator operating mode by calling :- int regulator_set_optimum_mode(struct regulator *regulator, int load_uA); int regulator_set_load(struct regulator *regulator, int load_uA); This will cause the core to recalculate the total load on the regulator (based on all its consumers) and change operating mode (if necessary and permitted) Loading
drivers/regulator/core.c +4 −4 Original line number Diff line number Diff line Loading @@ -2994,7 +2994,7 @@ unsigned int regulator_get_mode(struct regulator *regulator) EXPORT_SYMBOL_GPL(regulator_get_mode); /** * regulator_set_optimum_mode - set regulator optimum operating mode * regulator_set_load - set regulator load * @regulator: regulator source * @uA_load: load current * Loading @@ -3017,9 +3017,9 @@ EXPORT_SYMBOL_GPL(regulator_get_mode); * DRMS will sum the total requested load on the regulator and change * to the most efficient operating mode if platform constraints allow. * * Returns the new regulator mode or error. * On error a negative errno is returned. */ int regulator_set_optimum_mode(struct regulator *regulator, int uA_load) int regulator_set_load(struct regulator *regulator, int uA_load) { struct regulator_dev *rdev = regulator->rdev; int ret; Loading @@ -3031,7 +3031,7 @@ int regulator_set_optimum_mode(struct regulator *regulator, int uA_load) return ret; } EXPORT_SYMBOL_GPL(regulator_set_optimum_mode); EXPORT_SYMBOL_GPL(regulator_set_load); /** * regulator_allow_bypass - allow the regulator to go into bypass mode Loading
include/linux/regulator/consumer.h +9 −3 Original line number Diff line number Diff line Loading @@ -238,7 +238,7 @@ int regulator_get_current_limit(struct regulator *regulator); int regulator_set_mode(struct regulator *regulator, unsigned int mode); unsigned int regulator_get_mode(struct regulator *regulator); int regulator_set_optimum_mode(struct regulator *regulator, int load_uA); int regulator_set_load(struct regulator *regulator, int load_uA); int regulator_allow_bypass(struct regulator *regulator, bool allow); Loading Loading @@ -479,8 +479,7 @@ static inline unsigned int regulator_get_mode(struct regulator *regulator) return REGULATOR_MODE_NORMAL; } static inline int regulator_set_optimum_mode(struct regulator *regulator, int load_uA) static inline int regulator_set_load(struct regulator *regulator, int load_uA) { return REGULATOR_MODE_NORMAL; } Loading Loading @@ -555,4 +554,11 @@ static inline int regulator_is_supported_voltage_tol(struct regulator *regulator target_uV + tol_uV); } /* TEMP: Wrapper to keep bisectability */ static inline int regulator_set_optimum_mode(struct regulator *regulator, int load_uA) { return regulator_set_load(regulator, load_uA); } #endif