Commit dee0df84 authored by Hans de Goede's avatar Hans de Goede Committed by Sebastian Reichel
Browse files

power: supply: bq25890: Always take HiZ mode into account for ADC rate



The code to check if F_CONV_RATE has been set, or if a manual ADC
conversion needs to be triggered, as well as the code to set
the initial F_CONV_RATE value at probe both where not taking
HiZ mode into account. Add checks for this.

Reviewed-by: default avatarMarek Vasut <marex@denx.de>
Signed-off-by: default avatarHans de Goede <hdegoede@redhat.com>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
parent 4413f9e9
Loading
Loading
Loading
Loading
+2 −2
Original line number Diff line number Diff line
@@ -467,7 +467,7 @@ static void bq25890_update_state(struct bq25890_device *bq,
	/* update state in case we lost an interrupt */
	__bq25890_handle_irq(bq);
	*state = bq->state;
	do_adc_conv = !state->online && bq25890_is_adc_property(psp);
	do_adc_conv = (!state->online || state->hiz) && bq25890_is_adc_property(psp);
	if (do_adc_conv)
		bq25890_field_write(bq, F_CONV_START, 1);
	mutex_unlock(&bq->lock);
@@ -956,7 +956,7 @@ static int bq25890_hw_init(struct bq25890_device *bq)
	}

	/* Configure ADC for continuous conversions when charging */
	ret = bq25890_field_write(bq, F_CONV_RATE, !!bq->state.online);
	ret = bq25890_field_write(bq, F_CONV_RATE, bq->state.online && !bq->state.hiz);
	if (ret < 0) {
		dev_dbg(bq->dev, "Config ADC failed %d\n", ret);
		return ret;