Commit de70cc33 authored by James Morse's avatar James Morse Committed by Zeng Heng
Browse files

arm_mpam: Reset MSC controls from cpu hp callbacks

maillist inclusion
category: feature
bugzilla: https://gitee.com/openeuler/kernel/issues/I8T2RT

Reference: https://git.kernel.org/pub/scm/linux/kernel/git/morse/linux.git/log/?h=mpam/snapshot/v6.7-rc2



---------------------------

When a CPU comes online, it may bring a newly accessible MSC with
it. Only the default partid has its value reset by hardware, and
even then the MSC might not have been reset since its config was
previously dirtyied. e.g. Kexec.

Any in-use partid must have its configuration restored, or reset.
In-use partids may be held in caches and evicted later.

MSC are also reset when CPUs are taken offline to cover cases where
firmware doesn't reset the MSC over reboot using UEFI, or kexec
where there is no firmware involvement.

If the configuration for a RIS has not been touched since it was
brought online, it does not need resetting again.

To reset, write the maximum values for all discovered controls.

CC: Rohit Mathew <Rohit.Mathew@arm.com>
Signed-off-by: default avatarJames Morse <james.morse@arm.com>
Signed-off-by: default avatarZeng Heng <zengheng4@huawei.com>
parent 931c0972