Add entries from Documentation/ABI/testing/sysfs-bus-iio-scd30
to Documentation/ABI/testing/sysfs-bus-iio. The attributes of the scd4x
and scd30 are common.

Remove Documentation/ABI/testing/sysfs-bus-iio-scd30.

Signed-off-by: default avatarRoan van Dijk <roan@protonic.nl>
Link: https://lore.kernel.org/r/20211008101706.755942-5-roan@protonic.nl


Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
parent 49d22b69
Loading
Loading
Loading
Loading
+41 −0
Original line number Diff line number Diff line
@@ -1958,3 +1958,44 @@ Description:
		Specify the percent for light sensor relative to the channel
		absolute value that a data field should change before an event
		is generated. Units are a percentage of the prior reading.

What:		/sys/bus/iio/devices/iio:deviceX/calibration_auto_enable
Date:		June 2020
KernelVersion:	5.8
Contact:	linux-iio@vger.kernel.org
Description:
		Some sensors have the ability to apply auto calibration at
		runtime. For example, it may be necessary to compensate for
		contaminant build-up in a measurement chamber or optical
		element deterioration that would otherwise lead to sensor drift.

		Writing 1 or 0 to this attribute will respectively activate or
		deactivate this auto calibration function.

		Upon reading, the current status is returned.

What:		/sys/bus/iio/devices/iio:deviceX/calibration_forced_value
Date:		June 2020
KernelVersion:	5.8
Contact:	linux-iio@vger.kernel.org
Description:
		Some sensors have the ability to apply a manual calibration using
		a known measurement value, perhaps obtained from an external
		reference device.

		Writing a value to this function will force such a calibration
		change. For the scd30 the value should be from the range
		[400 1 2000].

		Note for the scd30 that a valid value may only be obtained once
		it is has been written. Until then any read back of this value
		should be ignored. As for the scd4x an error will be returned
		immediately if the manual calibration has failed.

What:		/sys/bus/iio/devices/iio:deviceX/calibration_forced_value_available
KernelVersion:  5.15
Contact:        linux-iio@vger.kernel.org
Description:
		Available range for the forced calibration value, expressed as:

		- a range specified as "[min step max]"
+0 −34
Original line number Diff line number Diff line
What:		/sys/bus/iio/devices/iio:deviceX/calibration_auto_enable
Date:		June 2020
KernelVersion:	5.8
Contact:	linux-iio@vger.kernel.org
Description:
		Contaminants build-up in the measurement chamber or optical
		elements deterioration leads to sensor drift.

		One can compensate for sensor drift by using automatic self
		calibration procedure (asc).

		Writing 1 or 0 to this attribute will respectively activate or
		deactivate asc.

		Upon reading current asc status is returned.

What:		/sys/bus/iio/devices/iio:deviceX/calibration_forced_value
Date:		June 2020
KernelVersion:	5.8
Contact:	linux-iio@vger.kernel.org
Description:
		Contaminants build-up in the measurement chamber or optical
		elements deterioration leads to sensor drift.

		One can compensate for sensor drift by using forced
		recalibration (frc). This is useful in case there's known
		co2 reference available nearby the sensor.

		Picking value from the range [400 1 2000] and writing it to the
		sensor will set frc.

		Upon reading current frc value is returned. Note that after
		power cycling default value (i.e 400) is returned even though
		internally sensor had recalibrated itself.