power: supply: ab8500: Swap max and overvoltage



We should terminate charging when we reach the voltage_max_design_uv
not overvoltage_limit_uv, this is an abuse of that struct member.

The overvoltage limit is actually not configurable on the AB8500,
it is fixed to 4.75 V so drop a comment about that in the code.

Fixes: 2a5f4183 ("power: supply: ab8500: Standardize voltages")
Signed-off-by: default avatarLinus Walleij <linus.walleij@linaro.org>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
parent d58964be
Loading
Loading
Loading
Loading
+3 −5
Original line number Diff line number Diff line
@@ -186,13 +186,11 @@ int ab8500_bm_of_probe(struct power_supply *psy,
	 * fall back to safe defaults.
	 */
	if ((bi->voltage_min_design_uv < 0) ||
	    (bi->voltage_max_design_uv < 0) ||
	    (bi->overvoltage_limit_uv < 0)) {
	    (bi->voltage_max_design_uv < 0)) {
		/* Nominal voltage is 3.7V for unknown batteries */
		bi->voltage_min_design_uv = 3700000;
		bi->voltage_max_design_uv = 3700000;
		/* Termination voltage (overcharge limit) 4.05V */
		bi->overvoltage_limit_uv = 4050000;
		/* Termination voltage 4.05V */
		bi->voltage_max_design_uv = 4050000;
	}

	if (bi->constant_charge_current_max_ua < 0)
+1 −1
Original line number Diff line number Diff line
@@ -802,7 +802,7 @@ static void ab8500_chargalg_end_of_charge(struct ab8500_chargalg *di)
	if (di->charge_status == POWER_SUPPLY_STATUS_CHARGING &&
		di->charge_state == STATE_NORMAL &&
		!di->maintenance_chg && (di->batt_data.volt_uv >=
		di->bm->bi->overvoltage_limit_uv ||
		di->bm->bi->voltage_max_design_uv ||
		di->events.usb_cv_active || di->events.ac_cv_active) &&
		di->batt_data.avg_curr_ua <
		di->bm->bi->charge_term_current_ua &&
+7 −1
Original line number Diff line number Diff line
@@ -2263,7 +2263,13 @@ static int ab8500_fg_init_hw_registers(struct ab8500_fg *di)
{
	int ret;

	/* Set VBAT OVV threshold */
	/*
	 * Set VBAT OVV (overvoltage) threshold to 4.75V (typ) this is what
	 * the hardware supports, nothing else can be configured in hardware.
	 * See this as an "outer limit" where the charger will certainly
	 * shut down. Other (lower) overvoltage levels need to be implemented
	 * in software.
	 */
	ret = abx500_mask_and_set_register_interruptible(di->dev,
		AB8500_CHARGER,
		AB8500_BATT_OVV,