F54 diagnostics report functions provide data based on the number of enabled rx and tx electrodes, which is not identical to the number of electrodes reported with F54:Query0 and F54:Query1. Those values report the number of supported electrodes, not the number of enabled electrodes. The number of enabled electrodes can be determined by analyzing F55:Ctrl1 (sensor receiver assignment) and F55:Ctrl2 (sensor transmitter assignment). Propagate the number of enabled electrodes from F55 to F54 to avoid corrupted output if not all electrodes are enabled. Fixes: 3a762dbd ("[media] Input: synaptics-rmi4 - add support for F54 ...") Signed-off-by:Guenter Roeck <linux@roeck-us.net> Tested-by:
Nick Dyer <nick@shmanahar.org> Signed-off-by:
Dmitry Torokhov <dmitry.torokhov@gmail.com>