Commit a3cd66d7 authored by Potin Lai's avatar Potin Lai Committed by Guenter Roeck
Browse files

hwmon: (adm1275) Allow setting sample averaging



Current driver assume PWR_AVG and VI_AVG as 1 by default, and user needs
to set sample averaging via sysfs manually.

This patch parses the properties "adi,power-sample-average" and
"adi,volt-curr-sample-average" from device tree, and setting sample
averaging during probe. Input value must be one of value in the
list [1, 2, 4, 8, 16, 32, 64, 128].

Signed-off-by: default avatarPotin Lai <potin.lai@quantatw.com>
Link: https://lore.kernel.org/r/20220302123817.27025-2-potin.lai@quantatw.com


Signed-off-by: default avatarGuenter Roeck <linux@roeck-us.net>
parent f53bfe4d
Loading
Loading
Loading
Loading
+39 −1
Original line number Diff line number Diff line
@@ -475,6 +475,7 @@ static int adm1275_probe(struct i2c_client *client)
	int vindex = -1, voindex = -1, cindex = -1, pindex = -1;
	int tindex = -1;
	u32 shunt;
	u32 avg;

	if (!i2c_check_functionality(client->adapter,
				     I2C_FUNC_SMBUS_READ_BYTE_DATA
@@ -687,7 +688,7 @@ static int adm1275_probe(struct i2c_client *client)
		if ((config & (ADM1278_VOUT_EN | ADM1278_TEMP1_EN)) !=
		    (ADM1278_VOUT_EN | ADM1278_TEMP1_EN)) {
			config |= ADM1278_VOUT_EN | ADM1278_TEMP1_EN;
			ret = i2c_smbus_write_byte_data(client,
			ret = i2c_smbus_write_word_data(client,
							ADM1275_PMON_CONFIG,
							config);
			if (ret < 0) {
@@ -756,6 +757,43 @@ static int adm1275_probe(struct i2c_client *client)
		return -ENODEV;
	}

	if (data->have_power_sampling &&
	    of_property_read_u32(client->dev.of_node,
				 "adi,power-sample-average", &avg) == 0) {
		if (!avg || avg > ADM1275_SAMPLES_AVG_MAX ||
		    BIT(__fls(avg)) != avg) {
			dev_err(&client->dev,
				"Invalid number of power samples");
			return -EINVAL;
		}
		ret = adm1275_write_pmon_config(data, client, true,
						ilog2(avg));
		if (ret < 0) {
			dev_err(&client->dev,
				"Setting power sample averaging failed with error %d",
				ret);
			return ret;
		}
	}

	if (of_property_read_u32(client->dev.of_node,
				"adi,volt-curr-sample-average", &avg) == 0) {
		if (!avg || avg > ADM1275_SAMPLES_AVG_MAX ||
		    BIT(__fls(avg)) != avg) {
			dev_err(&client->dev,
				"Invalid number of voltage/current samples");
			return -EINVAL;
		}
		ret = adm1275_write_pmon_config(data, client, false,
						ilog2(avg));
		if (ret < 0) {
			dev_err(&client->dev,
				"Setting voltage and current sample averaging failed with error %d",
				ret);
			return ret;
		}
	}

	if (voindex < 0)
		voindex = vindex;
	if (vindex >= 0) {