Unverified Commit 7ad9f3d0 authored by Ondrej Jirman's avatar Ondrej Jirman Committed by Maxime Ripard
Browse files

ARM: dts: sun8i-h3: Add thermal trip points/cooling maps



This enables passive cooling by down-regulating CPU voltage
and frequency.

For trip points, I used a slightly lowered values from the BSP
code. The critical temperature of 110°C from BSP code seemed
like a lot, so I rounded it off to 100°C.

The critical trip point value is 30°C above the maximum recommended
ambient temperature (70°C) for the SoC from the datasheet, so there's
some headroom even at such a high ambient temperature.

Signed-off-by: default avatarOndrej Jirman <megous@megous.com>
Signed-off-by: default avatarMaxime Ripard <maxime@cerno.tech>
parent 4c7eeb9a
Loading
Loading
Loading
Loading
+25 −0
Original line number Diff line number Diff line
@@ -41,6 +41,7 @@
 */

#include "sunxi-h3-h5.dtsi"
#include <dt-bindings/thermal/thermal.h>

/ {
	cpu0_opp_table: opp_table0 {
@@ -227,6 +228,30 @@
			polling-delay-passive = <0>;
			polling-delay = <0>;
			thermal-sensors = <&ths 0>;

			trips {
				cpu_hot_trip: cpu-hot {
					temperature = <80000>;
					hysteresis = <2000>;
					type = "passive";
				};

				cpu_very_hot_trip: cpu-very-hot {
					temperature = <100000>;
					hysteresis = <0>;
					type = "critical";
				};
			};

			cooling-maps {
				cpu-hot-limit {
					trip = <&cpu_hot_trip>;
					cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
							 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
							 <&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
							 <&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
				};
			};
		};
	};
};