Commit 78d13552 authored by Riwen Lu's avatar Riwen Lu Committed by Guenter Roeck
Browse files

hwmon: (scpi-hwmon) shows the negative temperature properly



The scpi hwmon shows the sub-zero temperature in an unsigned integer,
which would confuse the users when the machine works in low temperature
environment. This shows the sub-zero temperature in an signed value and
users can get it properly from sensors.

Signed-off-by: default avatarRiwen Lu <luriwen@kylinos.cn>
Tested-by: default avatarXin Chen <chenxin@kylinos.cn>
Link: https://lore.kernel.org/r/20210604030959.736379-1-luriwen@kylinos.cn


Signed-off-by: default avatarGuenter Roeck <linux@roeck-us.net>
parent 7656cd21
Loading
Loading
Loading
Loading
+9 −0
Original line number Diff line number Diff line
@@ -99,6 +99,15 @@ scpi_show_sensor(struct device *dev, struct device_attribute *attr, char *buf)

	scpi_scale_reading(&value, sensor);

	/*
	 * Temperature sensor values are treated as signed values based on
	 * observation even though that is not explicitly specified, and
	 * because an unsigned u64 temperature does not really make practical
	 * sense especially when the temperature is below zero degrees Celsius.
	 */
	if (sensor->info.class == TEMPERATURE)
		return sprintf(buf, "%lld\n", (s64)value);

	return sprintf(buf, "%llu\n", value);
}