Commit 754f6117 authored by Nicholas Piggin's avatar Nicholas Piggin Committed by Michael Ellerman
Browse files

powerpc/64: switch asm helpers from GOT to TOC relative addressing



There is no need to use GOT addressing within the kernel.

Signed-off-by: default avatarNicholas Piggin <npiggin@gmail.com>
Signed-off-by: default avatarMichael Ellerman <mpe@ellerman.id.au>
Link: https://lore.kernel.org/r/20220926034057.2360083-4-npiggin@gmail.com
parent dab3b8f4
Loading
Loading
Loading
Loading
+2 −1
Original line number Diff line number Diff line
@@ -86,7 +86,8 @@

#ifdef CONFIG_PPC64_BOOT_WRAPPER
#define LOAD_REG_ADDR(reg,name)			\
	ld	reg,name@got(r2)
	addis	reg,r2,name@toc@ha;		\
	addi	reg,reg,name@toc@l
#else
#define LOAD_REG_ADDR(reg,name)			\
	lis	reg,name@ha;			\
+2 −1
Original line number Diff line number Diff line
@@ -337,7 +337,8 @@ GLUE(.,name):
	rldimi	reg, tmp, 32, 0

#define LOAD_REG_ADDR(reg,name)			\
	ld	reg,name@got(r2)
	addis	reg,r2,name@toc@ha;		\
	addi	reg,reg,name@toc@l

#define LOAD_REG_ADDRBASE(reg,name)	LOAD_REG_ADDR(reg,name)
#define ADDROFF(name)			0