Commit 72efa7eb authored by Jammy Zhou's avatar Jammy Zhou Committed by Alex Deucher
Browse files

drm/amdgpu: check context id for context switching (v2)



check the filp is not robust, and sometimes different contexts may
have same filp value.

v2: check both filp and ctx_id

Signed-off-by: default avatarJammy Zhou <Jammy.Zhou@amd.com>
Reviewed-by: default avatarChristian König <christian.koenig@amd.com>
parent 66b3cf2a
Loading
Loading
Loading
Loading
+1 −0
Original line number Diff line number Diff line
@@ -945,6 +945,7 @@ struct amdgpu_ring {
	unsigned		next_rptr_offs;
	unsigned		fence_offs;
	struct drm_file		*current_filp;
	unsigned		current_ctx;
	bool			need_ctx_switch;
	enum amdgpu_ring_type	type;
	char			name[16];
+3 −1
Original line number Diff line number Diff line
@@ -642,8 +642,10 @@ static int amdgpu_cs_ib_fill(struct amdgpu_device *adev,
			ib->is_const_ib = true;
		if (chunk_ib->flags & AMDGPU_IB_FLAG_GDS)
			ib->gds_needed = true;
		if (ib->ring->current_filp != parser->filp) {
		if ((ib->ring->current_filp != parser->filp) ||
		    (ib->ring->current_ctx != parser->ctx_id)) {
			ib->ring->need_ctx_switch = true;
			ib->ring->current_ctx = parser->ctx_id;
			ib->ring->current_filp = parser->filp;
		}