Commit 624bf42c authored by Yevgeny Kliteynik's avatar Yevgeny Kliteynik Committed by Saeed Mahameed
Browse files

net/mlx5: DR, Fix querying eswitch manager vport for ECPF



On BlueField the E-Switch manager is the ECPF (vport 0xFFFE), but when
querying capabilities of ECPF eswitch manager, need to query vport 0
with other_vport = 0.

Fixes: 9091b821 ("net/mlx5: DR, Handle eswitch manager and uplink vports separately")
Signed-off-by: default avatarYevgeny Kliteynik <kliteyn@nvidia.com>
Reviewed-by: default avatarAlex Vesker <valex@nvidia.com>
Signed-off-by: default avatarSaeed Mahameed <saeedm@nvidia.com>
parent 6b8b4258
Loading
Loading
Loading
Loading
+1 −3
Original line number Diff line number Diff line
@@ -164,9 +164,7 @@ static int dr_domain_query_vport(struct mlx5dr_domain *dmn,

static int dr_domain_query_esw_mngr(struct mlx5dr_domain *dmn)
{
	return dr_domain_query_vport(dmn,
				     dmn->info.caps.is_ecpf ? MLX5_VPORT_ECPF : 0,
				     false,
	return dr_domain_query_vport(dmn, 0, false,
				     &dmn->info.caps.vports.esw_manager_caps);
}