Commit 5467d5f9 authored by Vasileios Amoiridis's avatar Vasileios Amoiridis Committed by Wen Zhiwei
Browse files

iio: pressure: bmp280: Use BME prefix for BME280 specifics

stable inclusion
from stable-v6.6.55
commit 5da669d9ee26f39d671917e69812fd9c93d274d5
category: bugfix
bugzilla: https://gitee.com/openeuler/kernel/issues/IB0MX4

Reference: https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git/commit/?id=5da669d9ee26f39d671917e69812fd9c93d274d5



--------------------------------

[ Upstream commit b23be4cd99a6f1f46963b87952632268174e62c1 ]

Change the rest of the defines and function names that are
used specifically by the BME280 humidity sensor to BME280
as it is done for the rest of the BMP{0,1,3,5}80 sensors.

Signed-off-by: default avatarVasileios Amoiridis <vassilisamir@gmail.com>
Link: https://lore.kernel.org/r/20240429190046.24252-3-vassilisamir@gmail.com


Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
Stable-dep-of: b9065b0250e1 ("iio: pressure: bmp280: Fix regmap for BMP280 device")
Signed-off-by: default avatarSasha Levin <sashal@kernel.org>
Signed-off-by: default avatarWen Zhiwei <wenzhiwei@kylinos.cn>
parent 355eae56
Loading
Loading
Loading
Loading
+18 −19
Original line number Diff line number Diff line
@@ -234,14 +234,14 @@ static int bme280_read_calib(struct bmp280_data *data)
	 * Humidity data is only available on BME280.
	 */

	ret = regmap_read(data->regmap, BMP280_REG_COMP_H1, &tmp);
	ret = regmap_read(data->regmap, BME280_REG_COMP_H1, &tmp);
	if (ret < 0) {
		dev_err(dev, "failed to read H1 comp value\n");
		return ret;
	}
	calib->H1 = tmp;

	ret = regmap_bulk_read(data->regmap, BMP280_REG_COMP_H2,
	ret = regmap_bulk_read(data->regmap, BME280_REG_COMP_H2,
			       &data->le16, sizeof(data->le16));
	if (ret < 0) {
		dev_err(dev, "failed to read H2 comp value\n");
@@ -249,14 +249,14 @@ static int bme280_read_calib(struct bmp280_data *data)
	}
	calib->H2 = sign_extend32(le16_to_cpu(data->le16), 15);

	ret = regmap_read(data->regmap, BMP280_REG_COMP_H3, &tmp);
	ret = regmap_read(data->regmap, BME280_REG_COMP_H3, &tmp);
	if (ret < 0) {
		dev_err(dev, "failed to read H3 comp value\n");
		return ret;
	}
	calib->H3 = tmp;

	ret = regmap_bulk_read(data->regmap, BMP280_REG_COMP_H4,
	ret = regmap_bulk_read(data->regmap, BME280_REG_COMP_H4,
			       &data->be16, sizeof(data->be16));
	if (ret < 0) {
		dev_err(dev, "failed to read H4 comp value\n");
@@ -265,15 +265,15 @@ static int bme280_read_calib(struct bmp280_data *data)
	calib->H4 = sign_extend32(((be16_to_cpu(data->be16) >> 4) & 0xff0) |
				  (be16_to_cpu(data->be16) & 0xf), 11);

	ret = regmap_bulk_read(data->regmap, BMP280_REG_COMP_H5,
	ret = regmap_bulk_read(data->regmap, BME280_REG_COMP_H5,
			       &data->le16, sizeof(data->le16));
	if (ret < 0) {
		dev_err(dev, "failed to read H5 comp value\n");
		return ret;
	}
	calib->H5 = sign_extend32(FIELD_GET(BMP280_COMP_H5_MASK, le16_to_cpu(data->le16)), 11);
	calib->H5 = sign_extend32(FIELD_GET(BME280_COMP_H5_MASK, le16_to_cpu(data->le16)), 11);

	ret = regmap_read(data->regmap, BMP280_REG_COMP_H6, &tmp);
	ret = regmap_read(data->regmap, BME280_REG_COMP_H6, &tmp);
	if (ret < 0) {
		dev_err(dev, "failed to read H6 comp value\n");
		return ret;
@@ -289,7 +289,7 @@ static int bme280_read_calib(struct bmp280_data *data)
 *
 * Taken from BME280 datasheet, Section 4.2.3, "Compensation formula".
 */
static u32 bmp280_compensate_humidity(struct bmp280_data *data,
static u32 bme280_compensate_humidity(struct bmp280_data *data,
				      s32 adc_humidity)
{
	struct bmp280_calib *calib = &data->calib.bmp280;
@@ -429,7 +429,7 @@ static int bmp280_read_press(struct bmp280_data *data,
	return IIO_VAL_FRACTIONAL;
}

static int bmp280_read_humid(struct bmp280_data *data, int *val, int *val2)
static int bme280_read_humid(struct bmp280_data *data, int *val, int *val2)
{
	u32 comp_humidity;
	s32 adc_humidity;
@@ -440,7 +440,7 @@ static int bmp280_read_humid(struct bmp280_data *data, int *val, int *val2)
	if (ret < 0)
		return ret;

	ret = regmap_bulk_read(data->regmap, BMP280_REG_HUMIDITY_MSB,
	ret = regmap_bulk_read(data->regmap, BME280_REG_HUMIDITY_MSB,
			       &data->be16, sizeof(data->be16));
	if (ret < 0) {
		dev_err(data->dev, "failed to read humidity\n");
@@ -453,7 +453,7 @@ static int bmp280_read_humid(struct bmp280_data *data, int *val, int *val2)
		dev_err(data->dev, "reading humidity skipped\n");
		return -EIO;
	}
	comp_humidity = bmp280_compensate_humidity(data, adc_humidity);
	comp_humidity = bme280_compensate_humidity(data, adc_humidity);

	*val = comp_humidity * 1000 / 1024;

@@ -537,7 +537,7 @@ static int bmp280_read_raw(struct iio_dev *indio_dev,
	return ret;
}

static int bmp280_write_oversampling_ratio_humid(struct bmp280_data *data,
static int bme280_write_oversampling_ratio_humid(struct bmp280_data *data,
						 int val)
{
	const int *avail = data->chip_info->oversampling_humid_avail;
@@ -681,7 +681,7 @@ static int bmp280_write_raw(struct iio_dev *indio_dev,
		mutex_lock(&data->lock);
		switch (chan->type) {
		case IIO_HUMIDITYRELATIVE:
			ret = bmp280_write_oversampling_ratio_humid(data, val);
			ret = bme280_write_oversampling_ratio_humid(data, val);
			break;
		case IIO_PRESSURE:
			ret = bmp280_write_oversampling_ratio_press(data, val);
@@ -831,16 +831,15 @@ EXPORT_SYMBOL_NS(bmp280_chip_info, IIO_BMP280);

static int bme280_chip_config(struct bmp280_data *data)
{
	u8 osrs = FIELD_PREP(BMP280_OSRS_HUMIDITY_MASK, data->oversampling_humid + 1);
	u8 osrs = FIELD_PREP(BME280_OSRS_HUMIDITY_MASK, data->oversampling_humid + 1);
	int ret;

	/*
	 * Oversampling of humidity must be set before oversampling of
	 * temperature/pressure is set to become effective.
	 */
	ret = regmap_update_bits(data->regmap, BMP280_REG_CTRL_HUMIDITY,
				  BMP280_OSRS_HUMIDITY_MASK, osrs);

	ret = regmap_update_bits(data->regmap, BME280_REG_CTRL_HUMIDITY,
				 BME280_OSRS_HUMIDITY_MASK, osrs);
	if (ret < 0)
		return ret;

@@ -868,12 +867,12 @@ const struct bmp280_chip_info bme280_chip_info = {

	.oversampling_humid_avail = bmp280_oversampling_avail,
	.num_oversampling_humid_avail = ARRAY_SIZE(bmp280_oversampling_avail),
	.oversampling_humid_default = BMP280_OSRS_HUMIDITY_16X - 1,
	.oversampling_humid_default = BME280_OSRS_HUMIDITY_16X - 1,

	.chip_config = bme280_chip_config,
	.read_temp = bmp280_read_temp,
	.read_press = bmp280_read_press,
	.read_humid = bmp280_read_humid,
	.read_humid = bme280_read_humid,
	.read_calib = bme280_read_calib,
};
EXPORT_SYMBOL_NS(bme280_chip_info, IIO_BMP280);
+4 −4
Original line number Diff line number Diff line
@@ -45,7 +45,7 @@ static bool bmp280_is_writeable_reg(struct device *dev, unsigned int reg)
{
	switch (reg) {
	case BMP280_REG_CONFIG:
	case BMP280_REG_CTRL_HUMIDITY:
	case BME280_REG_CTRL_HUMIDITY:
	case BMP280_REG_CTRL_MEAS:
	case BMP280_REG_RESET:
		return true;
@@ -57,8 +57,8 @@ static bool bmp280_is_writeable_reg(struct device *dev, unsigned int reg)
static bool bmp280_is_volatile_reg(struct device *dev, unsigned int reg)
{
	switch (reg) {
	case BMP280_REG_HUMIDITY_LSB:
	case BMP280_REG_HUMIDITY_MSB:
	case BME280_REG_HUMIDITY_LSB:
	case BME280_REG_HUMIDITY_MSB:
	case BMP280_REG_TEMP_XLSB:
	case BMP280_REG_TEMP_LSB:
	case BMP280_REG_TEMP_MSB:
@@ -167,7 +167,7 @@ const struct regmap_config bmp280_regmap_config = {
	.reg_bits = 8,
	.val_bits = 8,

	.max_register = BMP280_REG_HUMIDITY_LSB,
	.max_register = BME280_REG_HUMIDITY_LSB,
	.cache_type = REGCACHE_RBTREE,

	.writeable_reg = bmp280_is_writeable_reg,
+24 −21
Original line number Diff line number Diff line
@@ -192,8 +192,6 @@
#define BMP380_PRESS_SKIPPED		0x800000

/* BMP280 specific registers */
#define BMP280_REG_HUMIDITY_LSB		0xFE
#define BMP280_REG_HUMIDITY_MSB		0xFD
#define BMP280_REG_TEMP_XLSB		0xFC
#define BMP280_REG_TEMP_LSB		0xFB
#define BMP280_REG_TEMP_MSB		0xFA
@@ -207,15 +205,6 @@
#define BMP280_REG_CONFIG		0xF5
#define BMP280_REG_CTRL_MEAS		0xF4
#define BMP280_REG_STATUS		0xF3
#define BMP280_REG_CTRL_HUMIDITY	0xF2

/* Due to non linear mapping, and data sizes we can't do a bulk read */
#define BMP280_REG_COMP_H1		0xA1
#define BMP280_REG_COMP_H2		0xE1
#define BMP280_REG_COMP_H3		0xE3
#define BMP280_REG_COMP_H4		0xE4
#define BMP280_REG_COMP_H5		0xE5
#define BMP280_REG_COMP_H6		0xE7

#define BMP280_REG_COMP_TEMP_START	0x88
#define BMP280_COMP_TEMP_REG_COUNT	6
@@ -223,8 +212,6 @@
#define BMP280_REG_COMP_PRESS_START	0x8E
#define BMP280_COMP_PRESS_REG_COUNT	18

#define BMP280_COMP_H5_MASK		GENMASK(15, 4)

#define BMP280_CONTIGUOUS_CALIB_REGS	(BMP280_COMP_TEMP_REG_COUNT + \
					 BMP280_COMP_PRESS_REG_COUNT)

@@ -235,14 +222,6 @@
#define BMP280_FILTER_8X		3
#define BMP280_FILTER_16X		4

#define BMP280_OSRS_HUMIDITY_MASK	GENMASK(2, 0)
#define BMP280_OSRS_HUMIDITY_SKIP	0
#define BMP280_OSRS_HUMIDITY_1X		1
#define BMP280_OSRS_HUMIDITY_2X		2
#define BMP280_OSRS_HUMIDITY_4X		3
#define BMP280_OSRS_HUMIDITY_8X		4
#define BMP280_OSRS_HUMIDITY_16X	5

#define BMP280_OSRS_TEMP_MASK		GENMASK(7, 5)
#define BMP280_OSRS_TEMP_SKIP		0
#define BMP280_OSRS_TEMP_1X		1
@@ -264,6 +243,30 @@
#define BMP280_MODE_FORCED		1
#define BMP280_MODE_NORMAL		3

/* BME280 specific registers */
#define BME280_REG_HUMIDITY_LSB		0xFE
#define BME280_REG_HUMIDITY_MSB		0xFD

#define BME280_REG_CTRL_HUMIDITY	0xF2

/* Due to non linear mapping, and data sizes we can't do a bulk read */
#define BME280_REG_COMP_H1		0xA1
#define BME280_REG_COMP_H2		0xE1
#define BME280_REG_COMP_H3		0xE3
#define BME280_REG_COMP_H4		0xE4
#define BME280_REG_COMP_H5		0xE5
#define BME280_REG_COMP_H6		0xE7

#define BME280_COMP_H5_MASK		GENMASK(15, 4)

#define BME280_OSRS_HUMIDITY_MASK	GENMASK(2, 0)
#define BME280_OSRS_HUMIDITY_SKIP	0
#define BME280_OSRS_HUMIDITY_1X		1
#define BME280_OSRS_HUMIDITY_2X		2
#define BME280_OSRS_HUMIDITY_4X		3
#define BME280_OSRS_HUMIDITY_8X		4
#define BME280_OSRS_HUMIDITY_16X	5

/* BMP180 specific registers */
#define BMP180_REG_OUT_XLSB		0xF8