Commit 4abbaf29 authored by Jonathan Cameron's avatar Jonathan Cameron
Browse files

iio:ABI docs: Combine sysfs-bus-iio-humidity-hdc2010/hdc100x into one file



These contain only one entry for out_current_heater_raw (_available).
Document this in a new sysfs-bus-iio-humidity file, and make it a little
more generic by allowing for non 0/1 values.

Fixes
$ scripts/get_abi.pl validate
Warning: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw is defined 2 times:  ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010:0  ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x:0
Warning: /sys/bus/iio/devices/iio:deviceX/out_current_heater_raw_available is defined 2 times:  ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc2010:1  ./Documentation/ABI/testing/sysfs-bus-iio-humidity-hdc100x:1

Cc: Eugene Zaikonnikov <ez@norphonic.com>
Cc: Matt Ranostay <matt.ranostay@konsulko.com>
Reported-by: default avatarMauro Carvalho Chehab <mchehab+huawei@kernel.org>
Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
Reviewed-by: default avatarMatt Ranostay <matt.ranostay@konsulko.com>
Link: https://lore.kernel.org/r/20210117153816.696693-6-jic23@kernel.org
parent b923561f
Loading
Loading
Loading
Loading
+2 −1
Original line number Diff line number Diff line
@@ -6,4 +6,5 @@ Description:
		Controls the heater device within the humidity sensor to get
		rid of excess condensation.

		Valid control values are 0 = OFF, and 1 = ON.
		In some devices, this is just a switch in which case 0 = OFF,
		and 1 = ON.
+0 −9
Original line number Diff line number Diff line
What:		/sys/bus/iio/devices/iio:deviceX/out_current_heater_raw
What:		/sys/bus/iio/devices/iio:deviceX/out_current_heater_raw_available
KernelVersion:	4.3
Contact:	linux-iio@vger.kernel.org
Description:
		Controls the heater device within the humidity sensor to get
		rid of excess condensation.

		Valid control values are 0 = OFF, and 1 = ON.