Commit 445c21d2 authored by Hans de Goede's avatar Hans de Goede Committed by Sebastian Reichel
Browse files

power: supply: bq24190_charger: Program charger with fwnode supplied ccc_ireg and cvc_vreg



So far the bq24190_charger driver has been relying on either the chips
default constant_charge_current_max_ua and constant_charge_voltage_max_uv
values, or on the BIOS or bootloader to program these for us.

This does not happen on all boards, causing e.g. the wrong (too low)
values to be used on Lenovo Yoga Tablet 2 830F/L and 1050F/L tablets.

If power_supply_get_battery_info() provides us with values for these
settings, then program the charger accordingly.

And if the user later overrides these values then save the user-values
so that these will be restored after a suspend/resume.

Signed-off-by: default avatarHans de Goede <hdegoede@redhat.com>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
parent 73633ccb
Loading
Loading
Loading
Loading
+49 −2
Original line number Diff line number Diff line
@@ -165,7 +165,9 @@ struct bq24190_dev_info {
	u16				sys_min;
	u16				iprechg;
	u16				iterm;
	u32				ichg;
	u32				ichg_max;
	u32				vreg;
	u32				vreg_max;
	struct mutex			f_reg_lock;
	u8				f_reg;
@@ -662,6 +664,28 @@ static int bq24190_set_config(struct bq24190_dev_info *bdi)
			return ret;
	}

	if (bdi->ichg) {
		ret = bq24190_set_field_val(bdi, BQ24190_REG_CCC,
					    BQ24190_REG_CCC_ICHG_MASK,
					    BQ24190_REG_CCC_ICHG_SHIFT,
					    bq24190_ccc_ichg_values,
					    ARRAY_SIZE(bq24190_ccc_ichg_values),
					    bdi->ichg);
		if (ret < 0)
			return ret;
	}

	if (bdi->vreg) {
		ret = bq24190_set_field_val(bdi, BQ24190_REG_CVC,
					    BQ24190_REG_CVC_VREG_MASK,
					    BQ24190_REG_CVC_VREG_SHIFT,
					    bq24190_cvc_vreg_values,
					    ARRAY_SIZE(bq24190_cvc_vreg_values),
					    bdi->vreg);
		if (ret < 0)
			return ret;
	}

	return 0;
}

@@ -995,10 +1019,16 @@ static int bq24190_charger_set_current(struct bq24190_dev_info *bdi,
	if (v)
		curr *= 5;

	return bq24190_set_field_val(bdi, BQ24190_REG_CCC,
	ret = bq24190_set_field_val(bdi, BQ24190_REG_CCC,
			BQ24190_REG_CCC_ICHG_MASK, BQ24190_REG_CCC_ICHG_SHIFT,
			bq24190_ccc_ichg_values,
			ARRAY_SIZE(bq24190_ccc_ichg_values), curr);
	if (ret < 0)
		return ret;

	bdi->ichg = curr;

	return 0;
}

static int bq24190_charger_get_voltage(struct bq24190_dev_info *bdi,
@@ -1020,10 +1050,18 @@ static int bq24190_charger_get_voltage(struct bq24190_dev_info *bdi,
static int bq24190_charger_set_voltage(struct bq24190_dev_info *bdi,
		const union power_supply_propval *val)
{
	return bq24190_set_field_val(bdi, BQ24190_REG_CVC,
	int ret;

	ret = bq24190_set_field_val(bdi, BQ24190_REG_CVC,
			BQ24190_REG_CVC_VREG_MASK, BQ24190_REG_CVC_VREG_SHIFT,
			bq24190_cvc_vreg_values,
			ARRAY_SIZE(bq24190_cvc_vreg_values), val->intval);
	if (ret < 0)
		return ret;

	bdi->vreg = val->intval;

	return 0;
}

static int bq24190_charger_get_iinlimit(struct bq24190_dev_info *bdi,
@@ -1701,6 +1739,15 @@ static int bq24190_get_config(struct bq24190_dev_info *bdi)
		else
			dev_warn(bdi->dev, "invalid value for battery:charge-term-current-microamp: %d\n",
				 v);

		/* These are optional, so no warning when not set */
		v = info->constant_charge_current_max_ua;
		if (v >= bq24190_ccc_ichg_values[0] && v <= bdi->ichg_max)
			bdi->ichg = v;

		v = info->constant_charge_voltage_max_uv;
		if (v >= bq24190_cvc_vreg_values[0] && v <= bdi->vreg_max)
			bdi->vreg = v;
	}

	return 0;