Commit 3f7ced7a authored by Lukasz Luba's avatar Lukasz Luba Committed by Daniel Lezcano
Browse files

drivers/thermal/cpufreq_cooling : Refactor thermal_power_cpu_get_power tracing



Simplify the thermal_power_cpu_get_power trace event by removing
complicated cpumask and variable length array. Now the tools parsing trace
output don't have to hassle to get this power data. The simplified format
version uses 'policy->cpu'. Remove also the 'load' information completely
since there is very little value of it in this trace event. To get the
CPUs' load (or utilization) there are other dedicated trace hooks in the
kernel. This patch also simplifies and speeds-up the main cooling code
when that trace event is enabled.

Rename the trace event to avoid confusion of tools which parse the trace
file.

Acked-by: default avatarViresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: default avatarLukasz Luba <lukasz.luba@arm.com>
Link: https://lore.kernel.org/r/20220613124327.30766-3-lukasz.luba@arm.com


Signed-off-by: default avatarDaniel Lezcano <daniel.lezcano@linaro.org>
parent 3cbf6a8a
Loading
Loading
Loading
Loading
+1 −17
Original line number Diff line number Diff line
@@ -216,16 +216,9 @@ static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev,
	u32 total_load = 0;
	struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
	struct cpufreq_policy *policy = cpufreq_cdev->policy;
	u32 *load_cpu = NULL;

	freq = cpufreq_quick_get(policy->cpu);

	if (trace_thermal_power_cpu_get_power_enabled()) {
		u32 ncpus = cpumask_weight(policy->related_cpus);

		load_cpu = kcalloc(ncpus, sizeof(*load_cpu), GFP_KERNEL);
	}

	for_each_cpu(cpu, policy->related_cpus) {
		u32 load;

@@ -235,22 +228,13 @@ static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev,
			load = 0;

		total_load += load;
		if (load_cpu)
			load_cpu[i] = load;

		i++;
	}

	cpufreq_cdev->last_load = total_load;

	*power = get_dynamic_power(cpufreq_cdev, freq);

	if (load_cpu) {
		trace_thermal_power_cpu_get_power(policy->related_cpus, freq,
						  load_cpu, i, *power);

		kfree(load_cpu);
	}
	trace_thermal_power_cpu_get_power_simple(policy->cpu, *power);

	return 0;
}
+8 −20
Original line number Diff line number Diff line
@@ -92,34 +92,22 @@ TRACE_EVENT(thermal_zone_trip,
);

#ifdef CONFIG_CPU_THERMAL
TRACE_EVENT(thermal_power_cpu_get_power,
	TP_PROTO(const struct cpumask *cpus, unsigned long freq, u32 *load,
		size_t load_len, u32 dynamic_power),
TRACE_EVENT(thermal_power_cpu_get_power_simple,
	TP_PROTO(int cpu, u32 power),

	TP_ARGS(cpus, freq, load, load_len, dynamic_power),
	TP_ARGS(cpu, power),

	TP_STRUCT__entry(
		__bitmask(cpumask, num_possible_cpus())
		__field(unsigned long, freq          )
		__dynamic_array(u32,   load, load_len)
		__field(size_t,        load_len      )
		__field(u32,           dynamic_power )
		__field(int, cpu)
		__field(u32, power)
	),

	TP_fast_assign(
		__assign_bitmask(cpumask, cpumask_bits(cpus),
				num_possible_cpus());
		__entry->freq = freq;
		memcpy(__get_dynamic_array(load), load,
			load_len * sizeof(*load));
		__entry->load_len = load_len;
		__entry->dynamic_power = dynamic_power;
		__entry->cpu = cpu;
		__entry->power = power;
	),

	TP_printk("cpus=%s freq=%lu load={%s} dynamic_power=%d",
		__get_bitmask(cpumask), __entry->freq,
		__print_array(__get_dynamic_array(load), __entry->load_len, 4),
		__entry->dynamic_power)
	TP_printk("cpu=%d power=%u", __entry->cpu, __entry->power)
);

TRACE_EVENT(thermal_power_cpu_limit,