auxdisplay: hd44780: move cursor home after clear display command



The DISPLAY_CLEAR command on the NewHaven NHD-0220DZW-AG5 display
does NOT change the DDRAM address to 00h (home position) like the
standard Hitachi HD44780 controller. As a consequence, the starting
position of the initial string LCD_INIT_TEXT is not guaranteed to be
at 0,0 depending on where the cursor was before the DISPLAY_CLEAR
command.

Extract of DISPLAY_CLEAR command from datasheets of:

    Hitachi HD44780:
        ... It then sets DDRAM address 0 into the address counter...

    NewHaven NHD-0220DZW-AG5 datasheet:
	... This instruction does not change the DDRAM Address

Move the cursor home after sending DISPLAY_CLEAR command to support
non-standard LCDs.

Signed-off-by: default avatarHugo Villeneuve <hvilleneuve@dimonoff.com>
Reviewed-by: default avatarGeert Uytterhoeven <geert@linux-m68k.org>
Tested-by: default avatarDavid Reaver <me@davidreaver.com>
Link: https://lore.kernel.org/r/20230722180925.1408885-1-hugo@hugovil.com


Signed-off-by: default avatarMiguel Ojeda <ojeda@kernel.org>
parent 2ccdd1b1
Loading
Loading
Loading
Loading
+9 −1
Original line number Diff line number Diff line
@@ -82,7 +82,15 @@ int hd44780_common_clear_display(struct charlcd *lcd)
	hdc->write_cmd(hdc, LCD_CMD_DISPLAY_CLEAR);
	/* datasheet says to wait 1,64 milliseconds */
	long_sleep(2);
	return 0;

	/*
	 * The Hitachi HD44780 controller (and compatible ones) reset the DDRAM
	 * address when executing the DISPLAY_CLEAR command, thus the
	 * following call is not required. However, other controllers do not
	 * (e.g. NewHaven NHD-0220DZW-AG5), thus move the cursor to home
	 * unconditionally to support both.
	 */
	return hd44780_common_home(lcd);
}