If there are outstanding LAYOUTGET rpc calls, then we want to ensure that
we keep the layout stateid around so we that don't inadvertently pick up
an old/misordered sequence id.
The race is as follows:
Client Server
====== ======
LAYOUTGET(seqid)
LAYOUTGET(seqid)
return LAYOUTGET(seqid+1)
return LAYOUTGET(seqid+2)
process LAYOUTGET(seqid+2)
forget layout
process LAYOUTGET(seqid+1)
If it forgets the layout stateid before processing seqid+1, then
the client will not check the layout->plh_barrier, and so will set
the stateid with seqid+1.