Commit 29e9eff4 authored by Lubomir Rintel's avatar Lubomir Rintel Committed by Sebastian Reichel
Browse files

power: supply: olpc_battery: fix the power supply name



The framework is unhappy about them, because it uses the names in sysfs
attributes:

  power_supply olpc-ac: hwmon: 'olpc-ac' is not a valid name attribute, please fix
  power_supply olpc-battery: hwmon: 'olpc-battery' is not a valid name attribute, please fix

See also commit 648cd48c ("hwmon: Do not accept invalid name
attributes") and commit 74d3b641 ("hwmon: Relax name attribute
validation for new APIs").

Signed-off-by: default avatarLubomir Rintel <lkundrak@v3.sk>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
parent fa7cc725
Loading
Loading
Loading
Loading
+2 −2
Original line number Diff line number Diff line
@@ -52,7 +52,7 @@ static const char * const lid_wake_mode_names[] = {

static void battery_status_changed(void)
{
	struct power_supply *psy = power_supply_get_by_name("olpc-battery");
	struct power_supply *psy = power_supply_get_by_name("olpc_battery");

	if (psy) {
		power_supply_changed(psy);
@@ -62,7 +62,7 @@ static void battery_status_changed(void)

static void ac_status_changed(void)
{
	struct power_supply *psy = power_supply_get_by_name("olpc-ac");
	struct power_supply *psy = power_supply_get_by_name("olpc_ac");

	if (psy) {
		power_supply_changed(psy);
+2 −2
Original line number Diff line number Diff line
@@ -75,7 +75,7 @@ static struct kobj_attribute lid_wake_on_close_attr =

static void battery_status_changed(void)
{
	struct power_supply *psy = power_supply_get_by_name("olpc-battery");
	struct power_supply *psy = power_supply_get_by_name("olpc_battery");

	if (psy) {
		power_supply_changed(psy);
@@ -85,7 +85,7 @@ static void battery_status_changed(void)

static void ac_status_changed(void)
{
	struct power_supply *psy = power_supply_get_by_name("olpc-ac");
	struct power_supply *psy = power_supply_get_by_name("olpc_ac");

	if (psy) {
		power_supply_changed(psy);
+2 −2
Original line number Diff line number Diff line
@@ -410,7 +410,7 @@ static void olpc_xo175_ec_complete(void *arg)
		dev_dbg(dev, "got event %.2x\n", byte);
		switch (byte) {
		case EVENT_AC_CHANGE:
			psy = power_supply_get_by_name("olpc-ac");
			psy = power_supply_get_by_name("olpc_ac");
			if (psy) {
				power_supply_changed(psy);
				power_supply_put(psy);
@@ -420,7 +420,7 @@ static void olpc_xo175_ec_complete(void *arg)
		case EVENT_BATTERY_CRITICAL:
		case EVENT_BATTERY_SOC_CHANGE:
		case EVENT_BATTERY_ERROR:
			psy = power_supply_get_by_name("olpc-battery");
			psy = power_supply_get_by_name("olpc_battery");
			if (psy) {
				power_supply_changed(psy);
				power_supply_put(psy);
+2 −2
Original line number Diff line number Diff line
@@ -88,7 +88,7 @@ static enum power_supply_property olpc_ac_props[] = {
};

static const struct power_supply_desc olpc_ac_desc = {
	.name = "olpc-ac",
	.name = "olpc_ac",
	.type = POWER_SUPPLY_TYPE_MAINS,
	.properties = olpc_ac_props,
	.num_properties = ARRAY_SIZE(olpc_ac_props),
@@ -605,7 +605,7 @@ static const struct attribute_group *olpc_bat_sysfs_groups[] = {
 *********************************************************************/

static struct power_supply_desc olpc_bat_desc = {
	.name = "olpc-battery",
	.name = "olpc_battery",
	.get_property = olpc_bat_get_property,
	.use_for_apm = 1,
};