Commit 20a5f5a9 authored by Christian König's avatar Christian König Committed by Alex Deucher
Browse files

drm/amdgpu: fix concurrent VM flushes on Vega/Navi v2



Starting with Vega the hardware supports concurrent flushes
of VMID which can be used to implement per process VMID
allocation.

But concurrent flushes are mutual exclusive with back to
back VMID allocations, fix this to avoid a VMID used in
two ways at the same time.

v2: don't set ring to NULL

Signed-off-by: default avatarChristian König <christian.koenig@amd.com>
Reviewed-by: default avatarJames Zhu <James.Zhu@amd.com>
Tested-by: default avatarJames Zhu <James.Zhu@amd.com>
Signed-off-by: default avatarAlex Deucher <alexander.deucher@amd.com>
Cc: stable@vger.kernel.org
parent d89f6048
Loading
Loading
Loading
Loading
+11 −8
Original line number Diff line number Diff line
@@ -215,7 +215,11 @@ static int amdgpu_vmid_grab_idle(struct amdgpu_vm *vm,
	/* Check if we have an idle VMID */
	i = 0;
	list_for_each_entry((*idle), &id_mgr->ids_lru, list) {
		fences[i] = amdgpu_sync_peek_fence(&(*idle)->active, ring);
		/* Don't use per engine and per process VMID at the same time */
		struct amdgpu_ring *r = adev->vm_manager.concurrent_flush ?
			NULL : ring;

		fences[i] = amdgpu_sync_peek_fence(&(*idle)->active, r);
		if (!fences[i])
			break;
		++i;
@@ -290,6 +294,10 @@ static int amdgpu_vmid_grab_reserved(struct amdgpu_vm *vm,
	     !dma_fence_is_signaled((*id)->last_flush))) {
		struct dma_fence *tmp;

		/* Don't use per engine and per process VMID at the same time */
		if (adev->vm_manager.concurrent_flush)
			ring = NULL;

		/* to prevent one context starved by another context */
		(*id)->pd_gpu_addr = 0;
		tmp = amdgpu_sync_peek_fence(&(*id)->active, ring);
@@ -365,12 +373,7 @@ static int amdgpu_vmid_grab_used(struct amdgpu_vm *vm,
		if (updates && (!flushed || dma_fence_is_later(updates, flushed)))
			needs_flush = true;

		/* Concurrent flushes are only possible starting with Vega10 and
		 * are broken on Navi10 and Navi14.
		 */
		if (needs_flush && (adev->asic_type < CHIP_VEGA10 ||
				    adev->asic_type == CHIP_NAVI10 ||
				    adev->asic_type == CHIP_NAVI14))
		if (needs_flush && !adev->vm_manager.concurrent_flush)
			continue;

		/* Good, we can use this VMID. Remember this submission as
+6 −0
Original line number Diff line number Diff line
@@ -3148,6 +3148,12 @@ void amdgpu_vm_manager_init(struct amdgpu_device *adev)
{
	unsigned i;

	/* Concurrent flushes are only possible starting with Vega10 and
	 * are broken on Navi10 and Navi14.
	 */
	adev->vm_manager.concurrent_flush = !(adev->asic_type < CHIP_VEGA10 ||
					      adev->asic_type == CHIP_NAVI10 ||
					      adev->asic_type == CHIP_NAVI14);
	amdgpu_vmid_mgr_init(adev);

	adev->vm_manager.fence_context =
+1 −0
Original line number Diff line number Diff line
@@ -331,6 +331,7 @@ struct amdgpu_vm_manager {
	/* Handling of VMIDs */
	struct amdgpu_vmid_mgr			id_mgr[AMDGPU_MAX_VMHUBS];
	unsigned int				first_kfd_vmid;
	bool					concurrent_flush;

	/* Handling of VM fences */
	u64					fence_context;